The IG8140 type four in one fixed online gas detector is a multi-function, intelligent and fully automatic detection instrument that is installed at a specific detection point 24h, which continuously detects gas concentration. The instrument has the function of accurate detection of gas concentration, at the same time, it has the detection of ambient temperature and humidity, and the pipeline installation and detection of pressure reducing and limiting flow function. The instrument outputs 4-20mA standard current signal, and has RS485 (Modbus RTU) signal output. It is compatible with all kinds of control alarm, PLC, DCS and other control systems, which can realize remote monitoring, remote alarm, data storage and other functions. The infrared remote control operation can complete the debugging and calibration remotely.
Technical Parameter
Gas combination | Range | Resolving power | Precision | Detection principle |
EX | 0-100%LEL | 0.1%LEL | ≤±3% | catalytic combustion |
CO | 0-100PPM | 0.01PPM | ≤±3% | Electrochemistry |
H2S | 0-50PPM | 0.1PPM | ≤±3% | catalytic combustion |
O2 | 0-25%VOL | 0.01%VOL | ≤±1% | Electrochemistry |
The project content | Specific parameters |
Repeatability | ≤±0.5% |
Response time | ≤15s(T90) |
The recovery time | ≤20s |
Display mode | 2.5 inch 320*240 high-definition color screen |
Detection mode | Fixed, on-line testing, diffusion or pump measurement, long-term continuous work |
Installation way | Wall hanging, pipe type, circulation type, pump suction type |
Form-factor | All aluminum alloy shell, electric spray fluorocarbon paint, explosion proof, corrosion resistant, durable and durable |
Explosion proof mark | ExdⅡCT6 |
Protection degree | IP65 |
Operating temperature | -20℃~+50℃ |
Operating humidity | ≤10%~95%RH |
OperatingPressure | ≤30Kpa |
Temperature display | -40℃~+120℃ 0.3℃ |
Humidity display | 0-100%RH 3%RH |
Communication interface | Automatic identification of infrared, USB and RS232 |
Printer | Infrared printer |
Data storage | 20 thousand sets of /20 million sets of data, extensible 32/64GB memory |
power source | 24VDC(12-30VDC) |
Size | 300×200×90mm(L×W×H) |
Weight | 2Kg |
Market / Application
Explosion-proof monitoring of flammable gas
Discarded emission monitoring of flue gas boiler
Safety monitoring of field operation
Oil, coal, chemical, municipal, fire, etc
Characteristic of instrument
★Using the latest nanotechnology 32 bit microprocessor technology, 24 bit ADC data acquisition chip, instruction execution nanosecond (NS) level;
★Built-in 32/64GB memory card, can store 100 thousand /20 million sets of data, can be custom set storage: according to the time period, only store the alarm value, all data storageFull of new data storage, replacing the old data, replacement time can customize the settings;
★The alarm value can be set arbitrarily, and the alarm mode is optional low alarm / high alarm / interval alarm / weighted average.
★The infrared remote control function can complete the single or batch calibration of the instrument, the signal output mode and the alarm set remotely through the remote control.
★Full range detection, high and low range automatic switching, the lowest can be detected 1ppb, 0.001ppm, the highest can be detected 99.999%Vol;
★With 4-20mA standard current signal output and RS485 (Modbus RTU) digital signal output at the same time;
★The instrument automatically identifies the infrared communication interface, the USB interface, the RS232 interface and communicates with the computer or uploads it to the computer. It can be selected as a wireless infrared printer.
★Built-in 220VAC or 5VDC or 24VDC 1A relay, which can control electrical equipment.
★A brushless vacuum pump can be automatically opened and closed automatically / manually, and a micro negative pressure environment can be used to detect the gas.
★With overloading protection function, grounding completely lightning protection, anti static magnetic field interference, automatic temperature compensation to the sensor;